Comparación in vitro de dos sistemas rotatorios para la desobturación de conductos radiculares distales en segundas molares inferiores

dc.contributor.advisorTorres Carrillo, Angelo Jose Socrates
dc.contributor.authorZabarburu Belloso, Pamela Ivon
dc.coverage.spatialChiclayoes_PE
dc.creatorZabarburu Belloso, Pamela Ivon
dc.date.accessioned2025-10-20T21:57:56Z
dc.date.embargoEnd2027-10-20
dc.date.issued2025
dc.description.abstractEl objetivo de este estudio fue comparar in vitro dos sistemas rotatorios para la desobturación de conductos de raíces distales segundas molares inferiores, mediante microtomografía computarizada (micro-CT), luego del uso de los instrumentos Re-treaty y Remover. Treinta y seis raíces distales de morales mandibulares, con un solo conducto ovalado fueron seleccionados, preparados con un instrumento R40(40.06) y rellenados con el sellador AH Plus y compactación lateral. Posteriormente se realizo la remoción con los sistemas Remover (n=18) y Re-treaty (n=18). Las muestras fueron escaneadas nuevamente, y a partir del volumen inicial de material de relleno y el volumen de material de relleno remanente en mm3 , se obtuvo el porcentaje de volumen de material remanente, donde el sistema Re-Treaty presentó un promedio de 9,28 mm³, mientras que el sistema Remover mostró 8,64 mm³. Aunque hubo diferencias numéricas, el análisis estadístico mediante la prueba de Mann–Whitney no reveló diferencias significativas (p = 0,874), lo que sugiere que ambos sistemas son comparables en cuanto a efectividad. Sin embargo, en relación con el tiempo necesario para lograr la desobturación completa, el sistema Remover fue significativamente más rápido, con un promedio de 292,58 segundos frente a 471,86 segundos del sistema Re-Treaty (p < 0,001). Esta diferencia estadísticamente significativa indica una mayor eficiencia del sistema Remover. En cuanto a la aparición de complicaciones durante el procedimiento, no se reportaron eventos adversos en ninguno de los grupos. En conclusión, aunque ambos sistemas mostraron una efectividad similar en términos de remoción del material.es_PE
dc.description.abstractThis in vitro study aimed to compare two rotary systems for the retreatment of distal canals of mandibular second molars using micro–computed tomography (micro-CT), following the use of Re-Treaty and Remover instruments. Thirty-six distal roots of mandibular molars, each with a single oval-shaped canal, were selected, prepared with an R40 (40.06) instrument, and filled using AH Plus sealer and lateral compaction. Retreatment was then performed with the Remover system (n = 18) or the Re-Treaty system (n = 18). The specimens were rescanned, and the percentage of residual filling material was calculated from the initial and remaining filling volumes (mm³). The mean residual volumes were 9.28 mm³ for Re-Treaty and 8.64 mm³ for Remover. Although numerical differences were observed, statistical analysis using the Mann–Whitney test revealed no significant difference (p = 0.874), indicating comparable effectiveness between systems. However, regarding the time required to achieve complete filling removal, the Remover system was significantly faster, with a mean of 292.58 seconds compared to 471.86 seconds for Re-Treaty (p < 0.001). This statistically significant difference demonstrates greater efficiency for the Remover system. No procedural complications or adverse events were recorded in either group. In conclusion, although both systems exhibited similar effectiveness in filling material removal, the Remover system achieved faster retreatment times.es_PE
dc.formatapplication/pdfes_PE
dc.identifier.citationZabarburu P. Comparación in vitro de dos sistemas rotatorios para la desobturación de conductos radiculares distales en segundas molares inferiores [Tesis de segunda especialidad]. Chiclayo: Universidad Católica Santo Toribio de Mogrovejo; 2025. 70 p. Disponible en:es_PE
dc.identifier.otherRTU008876
dc.identifier.urihttp://hdl.handle.net/20.500.12423/9234
dc.language.isospaes_PE
dc.publisherUniversidad Católica Santo Toribio de Mogrovejoes_PE
dc.publisher.countryPEes_PE
dc.rightshttps://purl.org/coar/access_right/c_f1cfes_PE
dc.rights.urihttps://creativecommons.org/licenses/by/4.0/es_PE
dc.subjectDesobturación
dc.subjectMicrotomografía
dc.subjectMolares inferiores
dc.subjectRoot canal retreatment
dc.subjectMicro-CT
dc.subjectMolar, mandibular
dc.subject.ocdehttps://purl.org/pe-repo/ocde/ford#3.02.14
dc.titleComparación in vitro de dos sistemas rotatorios para la desobturación de conductos radiculares distales en segundas molares inferiores
dc.typehttp://purl.org/coar/resource_type/c_7a1fes_PE
dc.type.versionhttp://purl.org/coar/version/c_970fb48d4fbd8a85
renati.advisor.dni46833225
renati.advisor.orcidhttps://orcid.org/0000-0003-1502-3881
renati.author.dni74201399
renati.discipline91109576es_PE
renati.jurorJaime Salloum, Luis
renati.jurorDiaz Silva, Carmen Lizeth
renati.jurorTorres Carrillo, Angelo José Sócrates
renati.levelhttps://purl.org/pe-repo/renati/level#tituloSegundaEspecialidades_PE
renati.typehttps://purl.org/pe-repo/renati/type#tesises_PE
thesis.degree.disciplineOdontología Carielogía y Endodonciaes_PE
thesis.degree.grantorUniversidad Católica Santo Toribio de Mogrovejo. Facultad de Medicinaes_PE
thesis.degree.nameSegunda Especialidad en Odontología Carielogía y Endodonciaes_PE
usat.lineaEducación en salud

Archivos

Bloque de licencias

Mostrando 1 - 1 de 1
No hay miniatura disponible
Nombre:
license.txt
Tamaño:
1.67 KB
Formato:
Item-specific license agreed upon to submission
Descripción: