Comparación in vitro de la resistencia a la fatiga cíclica de tres instrumentos rotacionales tipo blue en un conducto artificial curvo

Cargando...
Miniatura

Fecha

2025

Título de la revista

ISSN de la revista

Título del volumen

Editor

Universidad Católica Santo Toribio de Mogrovejo

Resumen

Los instrumentos endodónticos rotatorios con tratamiento térmico blue cumple la función de limpieza y preparación biomecánica y son de mucha ayuda para reducir el riesgo a las fracturas durante el procedimiento. Objetivo comparar las limas rotatorias S-blue, Blueshaper y Rotate VDW con respecto a la fatiga cíclica en un conducto curvo artificial. Materiales y métodos el estudio se ejecutó con un total de 36 limas dividido en 03 grupos de 12 en cada grupo : el primer grupo Rotate VDW de 25/06 en 3.5 N/cm y 400 rpm , el segundo grupo S-Blue 25/06 a 2.5 N/cm y 400rpm y el tercer grupo Blueshaper de 25/06 a 4 N/cm y 500rpm . Todas las limas se usaron de manera rotativa en un Endo motor woodpecker hasta que se fracturen en un aparato de acero con 60° de curvatura y una radio de 8mm .La cantidad de tiempo ejecutados hasta la ruptura se calculó en segundos con un cronómetro digital. La longitud del instrumento separado se mide con una regla calibrada. Resultados: si existió una diferencia significativa a comparar ala resistencia a la fatiga cíclica de los 03 sistemas rotatorios donde la S-Blue tiene menor resistencia a la fatiga favoreciendo al sistema Rotate VDW de ser más resistente.
Rotary endodontic instruments with blue heat treatment perform the function of cleaning and biomechanical preparation and are very helpful to reduce the risk of fractures during the procedure. Objective: to compare the rotary files S-blue, Blueshaper and Rotate VDW with respect to cyclic fatigue in an artificial curved canal. Materials and methods the study was executed with a total of 36 files divided into 03 groups of 12 in each group: the first group Rotate VDW of 25/06 at 3.5 N / cm and 400 rpm, the second group S-Blue 25/06 at 2.5 N / cm and 400 rpm and the third group Blueshaper 25/06 at 4 N / cm and 500 rpm. All files were used in a rotary manner in a Woodpecker Endo motor until they fractured in a steel apparatus with 60° curvature and an 8mm radius. The amount of time executed until breakage was calculated in seconds with a digital stopwatch. The length of the separated instrument was measured with a calibrated ruler. Results: There was a significant difference when comparing the cyclic fatigue resistance of the 03 rotary systems where the S-Blue had lower fatigue resistance favoring the Rotate VDW system as being more resistant.

Descripción

Palabras clave

Endodoncia, Instrumentos rotatorios, Fatiga cíclica, Endodontics, Rotary Instruments, Cyclic Fatigue

Citación

Cruz E. Comparación in vitro de la resistencia a la fatiga cíclica de tres instrumentos rotacionales tipo blue en un conducto artificial curvo [Tesis de segunda especialidad]. Chiclayo: Universidad Católica Santo Toribio de Mogrovejo; 2025. 34 p. Disponible en: